Adaptec AHA-3985 User's Guide Page 90

  • Download
  • Add to my manuals
  • Print
  • Page
    / 166
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 89
9-4
AHA-3980/3980W/3985/3985W User’s Guide
AHA-3980/3980W/3985/3985W User’s Guide
Stock Number: 510810-00, Rev. D Page: 9-4
Print Spec Number: 493479-00
Current Date: 3/1/99 ECN Date: 3/19/96
Changing the Priority of a Verification in Progress
If a verification is slowing other server operations unacceptably, you
can lower the priority of the verification on the server. You can also
speed a verification by increasing its priority. Change the priority at
either the Verify Menu or at the screen showing the Verify status bar:
From the Verify Menu, select
Change P
riority
. A prompt
appears, indicating the current priority and asking for the new
priority. Type a number from 0 through 9, where 0 is the lowest
priority.
From the Verify status bar screen, press
Esc
. From the menu
that appears, select
Change P
riority
. When prompted to select
a new priority, type a number from 0 through 9, where 0 is the
lowest priority.
Verification continues automatically, running at the new priority.
Testing Spare Disks
Routinely test any spare disks in an array—we recommend daily
testing. In this quick test, the Administrator utility sends a signal to
the spare and checks whether the disk responds. The test involves
no physical testing of the disk surface.
To test spare disks, use the Scheduler. Instructions are in
Scheduling
Tasks
on page 9-7.
Note:
If a test fails, the message Spare drive #
n
of
m
failed
Ready test appears onscreen. Verify that the drive has
power and that the cables are properly connected; then retry
the test. If the test still fails, the drive may have failed.
Reconstructing Data on a Replacement Disk
If you replace a failed disk in a mirrored or RAID 5 array, use the
Administrator utility to reconstruct the data on the replacement disk
(you cannot reconstruct data in a RAID 0 array). RAID 5 data is recon-
structed from the user and parity data on the good disks. RAID 1
data is copied from the other disk in the mirrored pair. Data is recon-
structed in the background, allowing you to continue working.