Appendix C: Using the Adaptec RAID Configuration Utility ● 99
Modifying Cache Settings
You can modify the read and write cache settings for an array. You can also modify the MaxIQ
cache settings. The MaxIQ cache uses the MaxIQ-compatible Solid State Drives in your system
as a read cache pool to improve performance in read-intensive applications.
Note:
For more information about MaxIQ, see Using the ACU to Manage the MaxIQ Pool on page
101.
To modify cache settings:
1 Select Manage Arrays from the main ACU menu.
2 Select the array, then press Ctrl+C.
The Modify Cache Settings window opens.
3 Enable or disable read caching.
4 Press Ta b.
5 Select the preferred MaxIQ setting (Enable/Disable), press Ta b, then enable or disable
MaxIQ.
Note:
To enable MaxIQ caching, read caching must also be enabled.
6
Press Ta b.
7 Enable or disable write caching: select Enable always for “write-back” caching; select
Disable for “write-through” caching.
8 Press Enter to accept the values.
Initializing Disk Drives
If a disk drive appears grayed-out (unavailable for use in a new array), it may need to be
initialized.
To begin initializing a disk drive, select Initialize Drives from the main ACU menu. You can
initialize one drive or multiple drives. If an error occurs during initialization, the message
“Initializing drives...FAILED x of n” is displayed. Press Enter to see a list of drives that failed to
initialize. Press Esc to continue.
Caution:
Do not initialize a disk drive that is part of an array. Initializing a disk drive that’s
part of an array may make the array unusable.
Back up all data from your disk drive before you initialize it.
Rescanning Disk Drives
To begin rescanning a disk drive, select Rescan Drives from the main ACU menu.
Power Off Drive After The duration of inactive state of the array/drive after which it is powered
off. This is an optional setting.
Note: Power Off Drive After duration should be greater than Slow
Down Drive After Duration.
Verify Drive After The regular time interval at which the system performs a health check of
the array/drive.
Option Description
Comments to this Manuals