Adaptec 9110G Specifications Page 20

  • Download
  • Add to my manuals
  • Print
  • Page
    / 38
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 19
16
Adaptec Fibre Card 9110G Users Reference
seconds to avoid NT timeouts (Event ID 9s on Windows NTs
System EventLog).
To increase the timeout value:
a Goto the Start button and select Run…
b For Windows NT 4, type:
a:\winnt4\timeout.reg
For Windows 2000, type:
a:\win2000\timeout.reg
c Select OK for the pop up window.
d You need to reboot in order for the registry setting to take
place.
2 N_port support:
If the switch is configured as an F_port, the adapter should be
configured as an N_port. When the adapter is configured as an
N_port, only one of the two connectors can be used (internal
HSSDC connector or the GBIC module).
To enable or disable N_Port:
a Goto the Start button and select Run…
b For Windows NT 4, type:
a:\winnt4\nport_on.reg
For Windows 2000, type:
a:\win2000\nport_on.reg
Replace nport_on.reg with nport_off.reg if you
would like to disable N_port support.
c Select OK for the pop up window.
d You need to reboot in order for the registry setting to take
place.
Page view 19
1 2 ... 15 16 17 18 19 20 21 22 23 24 25 ... 37 38

Comments to this Manuals

No comments