Adaptec 2120S - SCSI RAID Controller User's Guide Page 277

  • Download
  • Add to my manuals
  • Print
  • Page
    / 354
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 276
11-13
enclosure Commands
The following example prepares the device in slot 0 on enclosure
management device 0 for insertion or removal as a result of using
the enclosure prepare slot command:
AAC0>enclosure prepare slot 0 0
Executing: enclosure prepare slot 0 0
You may want to use the enclosure show slot command again
to see the change in the device slot’s status, as in the following
example:
AAC0>enclosure show slot
Executing: enclosure show slot
Enclosure Slot scsiId Insert Status
--------- ---- ------ ------- ------------------------------------------
0 0 0:00:0 4 OK UNCONFIG I/R READY NOTACTIVATE
0 1 0:01:0 0 OK UNCONFIG ACTIVATE
0 2 0:10:0 0 OK UNCONFIG ACTIVATE
0 3 0:03:0 0 OK UNCONFIG ACTIVATE
0 4 0:04:0 0 OK UNCONFIG ACTIVATE
1 0 1:00:0 0 OK CONFIG ACTIVATE
1 1 1:01:0 0 OK UNCONFIG ACTIVATE
1 2 1:10:0 0 OK UNCONFIG ACTIVATE
1 3 1:03:0 0 OK UNCONFIG ACTIVATE
1 4 1:04:0 0 OK UNCONFIG ACTIVATE
Note that the Status column now displays I/R READY and
NOTACTIVATE, which means the device slot is off and ready for
the insertion or removal of a device.
Related Information
enclosure commands:
enclosure activate slot (page 11-3)
enclosure identify slot (page 11-5)
enclosure list (page 11-7)
enclosure show slot (page 11-33)
Page view 276
1 2 ... 272 273 274 275 276 277 278 279 280 281 282 ... 353 354

Comments to this Manuals

No comments