A-8
Adaptec RAID Configuration Utility (ARC)
To initialize drives:
1 Restart the computer, then press Ctrl+A when prompted to
access the ARC utility.
2 From the ARC menu, select Array Configuration Utility.
3 Select Initialize Drives.
4 Browse with the arrow keys to select a channel.
5 Browse with the arrow keys to highlight the disk you want to
initialize, then press Insert.
6 Repeat Step 5 until all the drives to be initialized are selected.
7 Press Enter.
8 Read the warning message, ensure that you have selected the
correct drives to initialize, and then press Y to continue.
Rescanning Drives
To rescan the drives connected to the controller:
1 Restart the computer, then press Ctrl+A when prompted to
access the ARC utility.
2 From the ARC menu, select Array Configuration Utility.
3 Select Rescan Drives.