Adaptec 2010S - SCSI RAID Storage Controller User's Guide

Browse online or download User's Guide for RAID controllers Adaptec 2010S - SCSI RAID Storage Controller. Adaptec 2010S - SCSI RAID Storage Controller User`s guide [en] User Manual

Related models: 2015S

/ 128
Table of contents
STORAGE MANAGEMENT
SOFTWARE USER’S GUIDE
A
DAPTEC
SCSI RAID 2010S/ 2015S
Combined RAID SW-UG.book Page 1 Monday, September 9, 2002 1:25 PM

PDF file · ·

Print

Print document

Sharing

Summary of Contents

Page 1 - SOFTWARE USER’S GUIDE

STORAGE MANAGEMENT SOFTWARE USER’S GUIDE A DAPTEC SCSI RAID 2010S/ 2015S

Page 2 - Storage Management Software

R Adaptec Storage Management Software User’s Guide Combined RAID SW-UG.book Page i Monday, September 9, 2002 1:25 PM

Page 3 - Disclaimer

ii Copyright © 2002 Adaptec, Inc. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in…

Page 4

iii Adaptec Software License Agreement PLEASE READ CAREFULLY: THE USE OF THIS SOFTWARE IS SUBJECT TO THE SOFTWARE LICENSE TERMS OF ADAPTEC, INC. AND…

Page 5

iv 3. Ownership of Software. As Licensee, you own the media upon which the software is recorded or fixed, but Adaptec and its licensors retain title…

Page 6

v b. if Adaptec or its distributor is unable to deliver replacement media which is free from defects in materials or workmanship, you may terminate…

Page 7

vi Combined RAID SW-UG.book Page vi Monday, September 9, 2002 1:25 PM

Page 8 - Contents

vii Contents 1 Storage Management Software Overview 2 Storage Manager on ROM Overview 2-2 Keyboard Reference 2-3 Menu Control 2-3 Left Pane – Tree…

Page 9

viii Adaptec Storage Management Software User’s Guide Formatting a Drive 2-29 Upgrading Firmware – Flash HBA Option 2-30 Creating a SMOR Boot Disk…

Page 10

ix Command Statistics 3-47 Device I/O Statistics 3-47 Remote Communication 3-50 Connecting Across a Network 3-51 Installation and Configuration 3-51 4…

Page 11

x Adaptec Storage Management Software User’s Guide BDMI Introduction B-1 System Requirements B-2 Adaptec CI B-3 Installing DMI Support B-4 Adaptec DMI…

Page 12 - Software Overview

Storage Management Software Overview Your Adaptec RAID controller includes the following software tools to manage your storage subsystem: Storage…

Page 13

Storage Manager On ROM (SMOR)—A built-in utility that is part of the controller’s BIOS code. You can start SMOR by pressing Ctrl+A during BIOS…

Page 14

In this Chapter Overview 2-2 Keyboard Reference 2-3 Menu Reference 2-4 Icon Reference 2-6 Screen Layout 2-6 Running SMOR 2-9 Information and…

Page 15 - Overview

Overview Storage Manager on ROM (SMOR) is a BIOS-based setup utility that enables you to configure your Adaptec RAID controller without loading an…

Page 16 - Keyboard Reference

The array groups are accessible during the build process, with data protected; however RAID performance is at a reduced level until the build is…

Page 17 - Menu Reference

Left Pane – Tree View Control Right Pane – Information View Control Menu Reference The SMOR Main Menu changes dynamically depending on what is…

Page 18

File RAID Action Help Read System Config Rescan the system. Unsaved configuration changes are lost. Set System Config Save and enable configuration…

Page 19 - Screen Layout

Icon Reference SMOR uses the following icons in the Tree View: Screen Layout The SMOR interface works like the Windows Explorer tree- structured…

Page 20 - The Left Pane – Tree View

The Menu Bar To open a specific menu, press Alt+highlighted letter of the menu name. After a menu is open, you can select a specific menu item by…

Page 21

The Right Pane – Information View To the right of the component tree is the Information View pane. This area displays information related to the…

Page 22 - Running SMOR

Running SMOR Start SMOR by pressing Ctrl+A when the RAID controller BIOS message appears on the screen during the boot sequence. SMOR starts by…

Page 23 - Controller BIOS Settings

Information and Configuration Views When you highlight an item within the Tree View, the corresponding Information View is displayed. Controller BIOS…

Page 24

Enable SCSI CD-ROM Boot When enabled, the BIOS attempts to detect a bootable CD-ROM that uses the El-Torito format. This setting is disabled by…

Page 25 - Information Tab

Information Tab To view or change the configuration of the controller, highlight the controller in the Tree View. Available tabs are Information and…

Page 26 - Configuration Tab

Note: Adaptec RAID controllers report a cache size 16 MB less than the total installed memory value because the controller uses 16 MB as processor…

Page 27 - Bus Configuration Tab

Boot Enable This option enables you to modify the boot process for systems with multiple peripheral controllers in cases where the controller BIOS…

Page 28

Note: As reported means that the field displays the value returned by the controller firmware. Bus Each peripheral bus on a controller is assigned a…

Page 29 - Device Information Tab

Device Information Tab Individual devices are listed in the Tree View under the controller to which they are connected, as shown in Figures 2-7.…

Page 30

The status condition is one of the following for attached devices: The SCSI Capabilities section is a list of controller capabilities. A check mark…

Show all 128 pages
Page 31

Array and Array Group Information The Information tab for any array may be viewed by highlighting that array, as shown in Figure 2-8. Figure 2-8 Array…

Page 32

The Description section displays a general description of the highlighted array, as follows: The Status section displays the current status of the…

Page 33 - Array Operations

Setting the Configuration There are two configuration options on the File menu: Read System Config—Causes SMOR to rescan to detect any changes in…

Page 34

2 When the RAID Type window appears, select the RAID level you want to use. The default stripe size is selected automatically; however you can select…

Page 35

3 Select the devices you want to include in the array: a To add devices to the array, highlight the device and press the Spacebar. A check mark…

Page 36 - Deleting an Array

Creating a Multilevel RAID Creating a multilevel RAID (RAID 10 or 50) is similar to creating a normal RAID 1 or RAID 5 array group. To create a RAID10…

Page 37 - Hot Spares

2 A warning message appears, as shown in Figure 2-12. Select Yes or No. The array configuration for the devices is not deleted until you select File >…

Page 38 - Formatting a Drive

Rebuilding a Failed Array To replace a failed drive in an array that is not protected by an automatic hot spare, follow these steps: 1 Remove and…

Page 39

Upgrading Firmware – Flash HBA Option The firmware on your controller is upgradable using the Flash HBA option, which appears on the Action menu when…

Page 40 - Select OK button to start

4 Select Action > Flash HBA. The Source File Browser window appears, as shown in Figure 2-13. Figure 2-13 Source File Browser Window 5 In the Source…

Page 41 - Creating a SMOR Boot Disk

Creating a SMOR Boot Disk To create a SMOR boot disk, click Action > Make Boot Floppy or use the Adaptec RAID Installation CD. You may need a SMOR…

Page 42

In this Chapter Introduction 3-2 Installing Storage Manager 3-4 Running Storage Manager 3-5 Views 3-6 Status Reporting 3-22 Information Windows 3-22…

Page 43

Introduction Adaptec’s Storage Manager gives you complete control over your storage subsystem, enabling you to manage your storage locally or remotely…

Page 44

System Requirements Adaptec Storage Manager software and device drivers require approximately 4 MB of disk space. The host system should have at least…

Page 45 - Installing Storage Manager

Installing Storage Manager The original installation of the software starts with the installation instructions covered in chapter 4 of the Adaptec…

Page 46 - Running Storage Manager

. Figure 3-1 Storage Manager Setup Window Running Storage Manager You can run Storage Manager in one of the following ways: Locally—On the same…

Page 47 - Physical Configuration View

Views This section describes the two primary configuration views, which are: Physical Configuration View Logical Configuration View (includes Logical…

Page 48

Figures 3-2 shows a sample view of a Physical Configuration. Figure 3-2 Physical Configuration Window

Page 49 - Logical Configuration View

Logical Configuration View On the right side of the Logical Configuration View Window, shown in Figure 3-3, are all the physical devices that are…

Page 50

The tool bar at the top of the Logical Configuration View window contains the following buttons: Switch View Switches to the Logical Information View.…

Page 51 - Logical Device Addresses

Logical Device Addresses Every device and array is assigned a logical device address by Storage Manager. This is the address used by the host…

Page 52

The complete logical device address is composed of the following fields: Array groups are automatically assigned an address that corresponds to the…

Page 53 - Array Groups

Array Groups The tool bar at the top of the Logical Configuration View window, shown in Figure 3-4, contains the following buttons: You can use the…

Page 54 - Configuration View window

To view the Array Group Information window, shown in Figure 3-5, double-click the appropriate array icon in the Logical Configuration View window.…

Page 55

Note: The availability of the various buttons depends on the current configuration and state of the array. The toolbar at the bottom of the Array…

Page 56

1 Select the Create Array Group button. The Select Array Type window appears, as shown in Figure 3-6. Figure 3-6 Select Array Type Window 2 Select the…

Page 57

Click the drive icons you want to remove and then click Remove Drive. During the drive selection process some drives might be displayed in a blue…

Page 58

you are prompted to select the direction of the copy as shown in Figure 3-7. Figure 3-7 Mirroring Drives in an Array If you want to monitor the…

Page 59

Expanding and Extending Arrays – Windows XP, Windows 2000 and Windows NT only The following definitions are used in this section: Array…

Page 60 - Expanding an Array Group

Requirements and Restrictions Array expansion has the following system requirements and restrictions. Windows XP, Windows 2000, Windows NT 4.0, Server…

Page 61

Note: If the drives are not in hot-pluggable carriers, power down the system before adding drives to the peripheral bus. 2 Start Storage Manager and…

Page 62

Note: If a drive fails during expansion, the expansion may complete successfully. However, the new, larger array remains in a degraded state until the…

Page 63 - Information Windows

An array is not physically deleted until you exit Storage Manager and choose to save changes or select File > Set System Configuration. Status…

Page 64

Double-click a controller or device icon to display an Information window for that controller or device. Host Bus Adapter Information Window This…

Page 65

The following buttons are available: Configure Host Bus Adapter Window Click Configure in the Host Bus Adapter Info window to modify hardware…

Page 66

The following buttons are available: Controller Caching – Windows NT only To ensure optimum performance, follow these steps: 1 Click Caching in the…

Page 67 - Flash Configuration Window

The Advisory setting allows the controller to use its own algorithms for cache management. This is more efficient than allowing the operating system…

Page 68

The current controller model, firmware version, and firmware type are displayed. To specify an image file for the flash operation, you can type a path…

Page 69 - Device Information Window

Device Information Window The Device Information Window is shown in Figure 3-11. Figure 3-11 SCSI Device Information Window

Page 70

The Device Information window displays the following information: RAID drives display the name and level of the array to which they belong and the…

Page 71 - Device Configuration Window

Device Configuration Window Click Configure in either Device Information or Array Group Information window to display the Device Configuration window…

Page 72

Saving the Subsystem Configuration The Storage Manager File menu has the following options: Note: If you reset the NVRAM on the controller, any…

Page 73 - Event Log

Events are generated for detected fault conditions as well as RAID status changes, and are described as follows: Event Log When events occur, they are…

Page 74

When the Event Log button is selected, the Event Logs window appears, as shown in Figure 3-13. Figure 3-13 Event Logs Window The Event Logs window…

Page 75 - Event Broadcaster

Note: Only the event messages that appear on the screen when you click Print are printed. Therefore, if you want to print specific messages, scroll…

Page 76 - ■ Red Hat 7.3

You can select or modify the following parameters: Broadcasters are available on the following operating systems: Windows XP, Windows 2000 and Windows…

Page 77

Windows XP, Windows 2000 & Windows NT The broadcaster collects events from the controller and records them to files in the c:\program…

Page 78

This window displays a list of the events submitted to the application log by the broadcaster, as well as other applications. Adaptec events are…

Page 79 - Windows NT only

Installing the Broadcaster When you install the controller driver, you automatically install the the broadcaster in /usr/dpt. During broadcaster…

Page 80

2 Establish a permanent connection to an Internet Service Provider (ISP) or create a dial-up networking connection to your ISP. 3 Configure your email…

Page 81 - Formatting Drives

Formatting Drives Your controller can perform a low-level format on attached hard drives in standard 512-byte format. This function is available from…

Page 82 - Drive Failures

Drive Failures Drive failures are indicated by flags, which differ depending on whether they refer to an array or a drive in an array. Failure…

Page 83 - Assigning Hot Spares

Rebuilding a Degraded Array When a drive in an array fails, and that drive is not protected by an automatic hot spare, the array can be restored to…

Page 84 - Running a Verify Process

You should reboot your operating system to ensure that the hot spare drive is recognized correctly. Hot spares are reserved to automatically replace…

Page 85 - Background Task Priority

Note: Data inconsistencies should not occur under normal conditions. However, a power failure that interrupts an array write operation can cause…

Page 86 - Controller I/O Statistics

Select Options > Background Task Priority to control the relative priority of I/O from the operating system and background tasks. Figure 3-15 shows…

Page 87 - Cache Statistics

To see the HBA statistics window, shown in Figure 3-16, click I/O Stats in the Host Bus Adapter Info Window. Figure 3-16 HBA Statistics Window Cache…

Page 88 - Device I/O Statistics

Command Statistics Device I/O Statistics The total number of sectors written to disk by the controller is described by the formula: Write – Backs +…

Page 89

I/O statistics are displayed in the Hard Drive I/O Statistics window, as shown in Figure 3-17. Figure 3-17 Hard Drive I/O Statistics Window The Hard…

Page 90

Environments with a large number of sequential reads should generate a high number of Read-Ahead Hits relative to Total Sectors. These hits reduce the…

Page 91 - Remote Communication

Remote Communication The Storage Manager Remote Communication feature enables you to use Storage Manager running on your local workstation to manage…

Page 92 - Client/Workstation

Connecting Across a Network Storage Manager can run as a client/server application across a network using a TCP/IP connection. The Storage Manager…

Page 93

You must configure remote communication before it can be used. For both workstations and servers, this is done by editing the Storage Manager…

Page 94

The following list shows all supported options. The value listed is the default; optional values are in parentheses. Setting up the Server If you are…

Page 95

Linux The Linux communication server is installed during the Storage Manager software install process. The server module is copied to /usr/dpt and…

Page 96

Connecting to Remote Systems Select Communication > Make Connection to use Storage Manager to manage the controller in a remote server system using…

Page 97

Making a Manual Connection In the Manual Connections section of the Available Connections window, there is one icon for each protocol that you…

Page 98 - Figure 3-22 Phonebook Window

Using the Phonebook You can save the server name, address, user name, and protocol of systems you frequently access in the Phonebook, shown in Figure…

Page 99

Using a Custom Connection Under the Custom Connections section of the Available Connections window, there is one icon for each system that you marked…

Page 100 - RAIDUTIL Command Line

RAIDUTIL Command Line Utility In this Chapter Introduction The command line utility (RAIDUTIL) performs operations as soon as it has enough…

Page 101 - Device Address Syntax

Exit Status RAIDUTIL exits with either of the following error status indications: Device Address Syntax When you use RAIDUTIL to specify a device or…

Page 102 - Command Line Switches

RAIDUTIL Command Line Utility Command Line Switches Following is a list of the switches available in RAIDUTIL for testing and controlling various…

Page 103 - RAID 5 3 to 64 drives

followed by a drive address as discussed in Device Address Syntax on page 4-2. Multiple drive addresses on a command line must always be separated by…

Page 104 - RAIDUTIL Command Line Utility

RAIDUTIL Command Line Utility -D Delete logical drives This command deletes the specified drives and returns their capacity to unassigned space. If…

Page 105 - Array Modification

-z Specify logical drive stripe size Specifies the stripe size (in KB) for new RAID 0 and RAID 5 logical drives. Valid stripe sizes are: 8, 16, 32…

Page 106 - RAID Operation

RAIDUTIL Command Line Utility RAID Operation -C Load/save configuration This switch has two options: A file name must follow the load or save…

Page 107 - Controller-Specific

Controller-Specific -a Action (task) control This switch has the following options which allow you to control tasks on the controller: Specify drives…

Page 108 - Hot Spare Control

RAIDUTIL Command Line Utility Hot Spare Control -h Create hot spare drive This switch creates one or more stand-alone hot spare drives. The drives…

Page 109

General Information and Feedback -? Display utility usage information This option displays a summary of the command usage information. This includes…

Page 110

RAIDUTIL Command Line Utility -I Display inquiry information This switch displays controller specific information, including firmware revision, BIOS…

Page 111

-P Pagination output Limits output to 22 lines, then prompts to press Enter to continue. Pressing Enter prints another 22 lines. Use this switch to…

Page 112 - Introduction

SNMP Introduction SNMP (Simple Network Management Protocol) is a group of network management specifications that includes the protocol itself, the…

Page 113 - Management Information Base

SNMP SNMP is widely used and supported on a variety of servers, workstations, bridges, routers, and hubs. SNMP support also includes other computer…

Page 114 - Adaptec MIB Information

SNMP Management Console The SNMP management console is usually a client workstation running SNMP-based management software. The console software can…

Page 115

Adaptec Controller group is a list of all Adaptec controllers in the system. This group contains the following information for each Controller…

Page 116

SNMP Device Inquiry data Device capacity and block size Device RAID level and status (Optimal, Failed, etc.) Adaptec Array group contains all the…

Page 117 - Management Consoles

What’s Included The Adaptec SNMP software components are included on the Adaptec RAID Installation CD. Specific components vary by operating system.…

Page 118 - Installing the MIB

SNMP Installing Adaptec SNMP Support The following topics describe how to install Adaptec SNMP software and SNMP support for Windows. Note: Ensure…

Page 119 - SNMP Architecture

SNMP Architecture Figure shows the relationship of the SNMP to the other elements in a system that includes a RAID controller. Figure A-1. SNMP…

Page 120 - Adaptec SNMP Subagent

SNMP Adaptec SNMP Subagent The Adaptec SNMP subagent attaches to the operating system- specific master agent to handle SNMP requests for objects…

Page 121

A-10 Adaptec Storage Management Software User’s Guide Combined RAID SW-UG.book Page 10 Monday, September 9, 2002 1:25 PM

Page 122

B-1 B DMI In this Chapter Introduction The Desktop Management Interface (DMI) is a standard developed by the Desktop Management Task Force (DMTF) to…

Page 123

B-2 Adaptec Storage Management Software User’s Guide DMI consists of three components: SP (Service Provider)—Manages the communication between the MA…

Page 124 - Adaptec CI

B-3 DMI Adaptec CI At startup time the CI gathers information about Adaptec RAID controllers and stores this information in a DMI format table. When…

Page 125 - Adaptec DMI Modules

B-4 Adaptec Storage Management Software User’s Guide Installing DMI Support Adaptec supplies the CI only. The SP and MI must be provided by the…

Page 126 - file

B-5 DMI The following is a list of groups contained in the Adaptec Mass Storage MIF file. For the attributes of each group, refer to the admpdmi.mif…

Page 128 - Milpitas, CA 95035

Adaptec, Inc. 691 South Milpitas Boulevard Milpitas, CA 95035 ©2002 Adaptec, Inc. All rights reserved. Adaptec, and the Adaptec logo are trademarks of…

More documents for RAID controllers Adaptec 2010S - SCSI RAID Storage Controller

Questions about Adaptec 2010S - SCSI RAID Storage Controller

No questions about this manual yet. Ask the first one.

Ask a question

We answer from the manual and name the page. The question appears on the site after it is checked.

All questions and answers ›

Related products and manuals for RAID controllers Adaptec 2010S - SCSI RAID Storage Controller