Adaptec SAS RAID Controllers Installation Guide Page 112

  • Download
  • Add to my manuals
  • Print
  • Page
    / 148
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 111
98 Sun StorageTek SAS RAID HBA Installation Guide March 2010
In this example, S represents the distributed spare, P represents the distributed parity
data.
FIGURE F-6 RAID 5EE Arrays
RAID 50 Arrays
A RAID 50 array is built from at least six disk drives configured as two or more
RAID 5 arrays, and stripes stored data and parity data across all disk drives in both
RAID 5 arrays. (For more information, see “RAID 5 Arrays” on page 96.)
The parity data provides data protection, and striping improves performance. RAID
50 arrays also provide high data transfer speeds.
Page view 111
1 2 ... 107 108 109 110 111 112 113 114 115 116 117 ... 147 148

Comments to this Manuals

No comments