Appendix D: Using the Array Configuration Utility for DOS 97
Sample Script for SATA Controllers
This is a sample ACU file that will initialize all disk drives connected to the SATA controller
and create a RAID 5 array with the disk drives on ports 0, 1, and 2.
Controller= 0,5:7:0
Controller Name=ICP ICP9087MA
Subsystem ID=0x2A1
Firmware Version=V5.1-0[6792]
Total Ports=8
Port 0 = 0:0:0 Maxtor 279.479GB 279.395GB
Port 1 = 0:1:0 Maxtor 279.479GB 279.395GB
Port 2 = 0:2:0 Maxtor 279.479GB 279.395GB
Array=MyData2
Type=RAID5
Size=Maximum
InitializeAll=Yes
Method=Build/Verify
Wait=No
Drives=0:0:0, 0:1:0, 0:2:0
End