Caution:
Channel A has three SCSI connec-
tors: J1, J5, and J8. Do not connect devices to
all three connectors at one time. At most,
only two of the three channel A connectors
can be used at the same time.
Terminating the SCSI Bus
The last physical SCSI device on each end of the SCSI
bus must be terminated. Termination must be
disabled on all other devices in the middle of the
SCSI bus. You may need to change the termination
setting on some devices in your computer system.
Terminating the Host Adapter
Host adapter termination is controlled by the
SCSI
Select
utility. The default setting is
Automatic
,
which works like this:
If the host adapter detects that devices are
attached to at least two connectors on channel A,
it disables its terminators. Otherwise, the termi-
nators are enabled. If the 50-pin connector is
used, the high byte termination is always
enabled.
Termination for Channel B is the same as channel
A, except that the internal 50-pin connector does
not apply.
If you need to change host adapter termination, com-
plete the physical installation, then run SCSI
Select
as
described
in
Configuring the Host Adapter
on page 9.
Termination in Multiple Computer Configurations
If you are setting up your SCSI bus so that SCSI
devices are shared by host adapters in two different
computers, you can enable your host adapter to pro-
vide termination power even when one computer is
powered
OFF
. To do this, place a jumper shunt on
jumper J7 if the second computer is connected to
SCSI Channel A or on jumper J6 if the second com-
puter is connected to SCSI Channel B.
This feature works only when one computer is
turned off, and the other computer connected to the